6515--Battery Packs and Wi-Fi Cards
Department of Veterans Affairs
Description
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS code is 339112 -Medical surgical instruments equipment and supplies, with an SBA small business size standard of 1,000 employees. Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The purpose of this procurement is to acquire SUREPOWER rechargeable lithium-ion battery packs and R Series WiFi Cards with Clock Sync, FIPS, for defibrillators used throughout the facility by Nursing staff. The batteries shall power the defibrillators used on crash carts. The R Series WiFi Cards shall provide network connectivity, with clock synchronization performed automatically through DXS after scheduled readiness tests. The anticipated requirement includes battery packs with 5.8 Ah capacity, high-density lithium-ion chemistry, a RunTime Indicator, automatic calibration readiness, and the ability to store use and maintenance history. The WiFi Cards shall meet the physical, wireless, security, environmental, certification, and operating-system requirements identified in the Statement of Work below. The contractor shall comply with the complete VA cybersecurity and privacy requirements included in the Statement of Work, including the requirements applicable to medical devices, specialized systems, wireless connectivity, FIPS-validated cryptography, patching, product integrity, incident reporting, and VA information-system access. STATEMENT OF WORK Description of Equipment Requested: SUREPOWER RECHARGEABLE LITHIUM-ION BATTERY PACK and R Series WiFi Card with Clock Sync, FIPS for defibrillators How Equipment Works: Batteries power the defibrillators to enable them to deliver a controlled electrical shock that depolarizes all heart muscle cells at once, stopping chaotic rhythms like ventricular fibrillation so the heart s natural pacemaker can restart a normal rhythm. This process is performed by devices such as AEDs, which analyze heart rhythms and shock only when needed. The R Series Wi Fi card enables network connectivity, while clock synchronization is performed automatically through DXS after scheduled readiness tests. Who Will Use This Equipment: Nursing staff Where it will be used: Throughout the facility Salient Characteristics: Battery Must have 5.8 Ah Capacity Must have High density lithium-ion chemistry Must have RunTime Indicator Must have Automatic calibration ready Must be able to store history of use and maintenance R Series Wifi Card Must have Standard: IEEE 802.11 a/b/g/n (single stream) Must have Interface: CompactFlash (CF) self contained CF to Wi Fi functionality (no host CPU load) Must have Bands: 2.4 GHz (2.412 2.462 GHz) & 5 GHz (5.180 5.825 GHz) Must have Data rates: Up to 65 Mbps (includes 54/58.5/52/39/26/19.5/13/6/5/5.5/2/1 Mbps) Must have Modulation: OFDM with BPSK, QPSK, 16QAM, 64QAM, CCK Must have Security: WPA/WPA2 PSK, WEP (64/128 bits), TKIP Must have Antenna: Embedded PCB printed, 1.30 dBi @ 2.4 GHz / 1.97 dBi @ 5 GHz Must have TX power: 9 dBm @ 802.11a, 14 dBm @ 802.11b, 11 dBm @ 802.11g, 10 dBm @ 802.11n, 8 dBm @ 802.11an Must have Sensitivity: 70 dBm @ 802.11a, 75 dBm @ 802.11b, 70 dBm @ 802.11g, 69 dBm @ 802.11n, 67 dBm @ 802.11an Must have Dimensions: 60.5 × 41.7 × 6.45 mm Must have Operating temp: 0 55 °C Must have Humidity: 20 % 95 % Must have Certifications: FCC, IC Must have OS support: Windows XP / 7 Additional Equipment Or Replacement Equipment (EE number): Replacement Equipment No EE#s - MVO Justification: Defibrillators are required for crash carts VA CYBERSECURITY AND PRIVACY LANGUAGE FOR INCLUSION IN ACQUISITIONS. See attached PDF file. If your company is interested in and capable of providing the required supplies/services, you MUST provide the information indicated below OR your intent, interest to participation, and information provided will not be considered as valid for research purposes. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements. For instances where your company cannot meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please explain. For instances where your company can meet the DRAFT/SALIENT CHARACTERISTICS/SOW requirement(s), please clearly show how your company meets/exceeds each requirement otherwise your response will be recorded as interest only . (2) Please review the list of DRAFT/SALIENT CHARACTERISTICS/SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned S
Truncated. Read the full description and attachments on SAM.gov.